| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | IFM |
| Model Number : | PI1709 |
| Certification : | 3C |
| Price : | 743$/piece |
| Payment Terms : | T/T |
| Supply Ability : | 1piece in stock |
| Delivery Time : | 3 day |
| Product characteristics | |||||||||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||||
| Measuring range | |||||||||||
| Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||
| Application | |||||||||||
| Special feature | Gold-plated contacts | ||||||||||
| Measuring element | ceramic-capacitive pressure measuring cell | ||||||||||
| Temperature monitoring | no | ||||||||||
| Application | flush mountable for the food and beverage industry | ||||||||||
| Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||||
| Medium temperature [°C] | -25...150 | ||||||||||
| Min. bursting pressure | 30000 mbar | 435 psi | 3000 kPa | ||||||||
| Pressure rating | 10000 mbar | 145 psi | 1000 kPa | ||||||||
| Vacuum resistance | [mbar] | -1000 | |||||||||
| Type of pressure | relative pressure; vacuum | ||||||||||
| No dead space | yes | ||||||||||
| MAWP (for applications according to CRN) | [bar] | 10 | |||||||||
| Electrical data | |||||||||||
| Operating voltage [V] | 18...30 DC | ||||||||||
| PM1709 | |||||||||||
| Flush pressure sensor | |||||||||||
| PM-1-1BREA01-E-ZVG/US | |||||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
| Protection class | III | ||||||||||
| Reverse polarity protection | yes | ||||||||||
| Integrated watchdog | yes | ||||||||||
| 2-wire | |||||||||||
| Current consumption | [mA] | 3.5...21.5 | |||||||||
| Power-on delay time | [s] | 1 | |||||||||
| 3-wire | |||||||||||
| Current consumption | [mA] | < 45 | |||||||||
| Power-on delay time | [s] | 0.5 | |||||||||
| Inputs / outputs | |||||||||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||||
| Outputs | |||||||||||
| Total number of outputs | 2 | ||||||||||
| Output signal | analogue signal; IO-Link; (configurable) | ||||||||||
| Number of digital outputs | 1; (IO-Link) | ||||||||||
| Number of analogue outputs | 1 | ||||||||||
| Analogue current output [mA] | 4...20; (scalable) | ||||||||||
| Max. load [Ω] | 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) | ||||||||||
| Short-circuit proof | yes | ||||||||||
| Overload protection | yes | ||||||||||
| Measuring/setting range | |||||||||||
| Measuring range | -1...1 bar | -1000...1000 mbar | -14.5...14.5 psi | -100...100 kPa | |||||||
| Analogue start point | -1000...600 mbar | -14.5...8.7 psi | -100...60 kPa | ||||||||
| Analogue endpoint | -600...1000 mbar | -8.7...14.5 psi | -60...100 kPa | ||||||||
| Insteps of | 1 mbar | 0.01 psi | 0.1 kPa | ||||||||
| Factory setting | ASP = -1000 mbar | AEP = 1000 mbar | |||||||||
| Accuracy / deviations | |||||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||
| Characteristics deviation [% of the span] | < ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) | ||||||||||
| Linearity deviation | [% of the span] | < ± 0,15; (Turn down 1:1) | |||||||||
| Hysteresis deviation | < ± 0,15; (Turn down 1:1) | ||||||||||
| [% of the span] | |||||||||||
| Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||
| Total deviation over temperature range | Temperature range | total deviation | |||||||||
| -25...15 °C | Characteristics deviation ± 0,05 % of the span / 10 K | ||||||||||
| 15...80 °C | Characteristics deviation | ||||||||||
| 80...150 °C | Characteristics deviation ± 0,1 % of the span / 10 K | ||||||||||
| Notes on the accuracy / deviation | for further details see section Diagrams and graphs | ||||||||||
| PM1709 | |||||||||||
| Flush pressure sensor | |||||||||||
| PM-1-1BREA01-E-ZVG/US | |||||||||||
| Response times | |||||||||||
| Damping for the analogue [s] | 0...4 | ||||||||||
| output dAA | |||||||||||
| 2-wire | |||||||||||
| Step response time analogue [ms] | 30 | ||||||||||
| output | |||||||||||
| 3-wire | |||||||||||
| Step response time analogue [ms] | 7 | ||||||||||
| output | |||||||||||
| Interfaces | |||||||||||
| Communication interface | IO-Link | ||||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||||
| IO-Link revision | 1.1 | ||||||||||
| SDCI standard | IEC 61131-9 | ||||||||||
| Profiles | Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||||||||
| SIO mode | no | ||||||||||
| Required master port type | A | ||||||||||
| Process data analogue | 3 | ||||||||||
| Min. process cycle time [ms] | 3.2 | ||||||||||
| IO-Link resolution pressure [mbar] | 0.5 | ||||||||||
| IO-Link functions (acyclical) | application specific tag; internal temperature | ||||||||||
| Supported DeviceIDs | Type of operation | DeviceID | |||||||||
| default | 667 | ||||||||||
| Operating conditions | |||||||||||
| Ambient temperature [°C] | -25...80 | ||||||||||
| Storage temperature [°C] | -40...100 | ||||||||||
| Protection | IP 67; IP 68; IP 69K | ||||||||||
| Tests / approvals | |||||||||||
| EMC | DIN EN 61000-6-2 | ||||||||||
| DIN EN 61000-6-3 | |||||||||||
| Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | |||||||||
| Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | |||||||||
| MTTF [years] | 323 | ||||||||||
| Note on approval | factory certificate available as download at www.factory-certificate.ifm | ||||||||||
| UL approval | UL Approval no. | J021 | |||||||||
| Mechanical data | |||||||||||
| Weight | [g] | 306.9 | |||||||||
| Housing | cylindrical | ||||||||||
| Dimensions | [mm] | Ø 30.2 / L = 111 | |||||||||
| Materials | stainless steel (316L/1.4404); PBT | ||||||||||
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4435); surface characteristics: Ra < 0,4 / Rz 4; PTFE | ||||||||||
| Min. pressure cycles | 100 million | ||||||||||
| Tightening torque | [Nm] | 35 | |||||||||
| Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||
| PM1709 | |||||||||||
| Flush pressure sensor | |||||||||||
| PM-1-1BREA01-E-ZVG/US | |||||||||||
| Remarks | |||||||||||
| Pack quantity | 1 pcs. | ||||||||||
| Electrical connection | |||||||||||
Connector: 1 x M12; coding: A; Contacts: gold-plated | |||||||||||
| Connection | |||||||||||
![]() | |||||||||||
| 1 connection for 2-wire operation ( analogue ) 2 connection for 3-wire operation ( analogue / IO-Link ) OUT1 : IO-Link OUT2 : analogue output | |||||||||||
| PM1709 | |||||||||||
| Flush pressure sensor | |||||||||||
| PM-1-1BREA01-E-ZVG/US | |||||||||||
| Diagrams and graphs | |||||||||||
| ambient temperature influence on | X temperatureY total deviation | ||||||||||
| the accuracy | |||||||||||
|