| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | IFM |
| Model Number : | VKV021 |
| Certification : | 3C |
| Price : | $291/piece |
| Payment Terms : | T/T |
| Supply Ability : | 1piece in stock |
| Delivery Time : | 3 day |
| Product characteristics | |||||||||||
| Vibration monitor | |||||||||||
| VKV | |||||||||||
| Connection via M12 connector | |||||||||||
| Vibration monitor to DIN ISO 10816 | |||||||||||
| Measuring range RMS: 0...25 mm/s | |||||||||||
| Switching output NC DC PNP and analogue output 4...20 mA | |||||||||||
| Application | |||||||||||
| Electrical data | |||||||||||
| 18...32 DC | |||||||||||
| < 50 | |||||||||||
| Inputs / outputs | |||||||||||
| Circuit | 1 x normally closed DC PNP / 1 x analogue 4...20mA | ||||||||||
| Inputs / outputs total | 2 | ||||||||||
| Outputs | |||||||||||
| Digital | |||||||||||
| Output function | 1 x normally closed DC PNP | ||||||||||
| Max. current load per output | [mA] | 500 | |||||||||
| Voltage drop | [V] | < 2 | |||||||||
| Short-circuit protection | pulsed | ||||||||||
| Overload protection | yes | ||||||||||
| analogue current output | [mA] | 4...20 | |||||||||
| Max. load | [Ω] | < 500 | |||||||||
| Measuring / setting range | |||||||||||
| Delay [s] | 1...60 | ||||||||||
| 0...25 RMS | |||||||||||
| Accuracy / deviations | |||||||||||
| Accuracy [% of the final value] Switch point accuracy | < ± 3 | ||||||||||
| < ±4 | |||||||||||
| e koreoo | |||||||||||
| VKV021 | |||||||||||
| VIBRATION MONITOR | Diagnostic systems | ||||||||||
| Repeatability | < 0.5 % | ||||||||||
| Linearity | 0.25 % | ||||||||||
| Software / programming | |||||||||||
| Switch point setting | Setting ring | ||||||||||
| Switching delay | Setting ring | ||||||||||
| Environment | |||||||||||
| -25...80, for UL applications: max. 80 °C | |||||||||||
| Protection | IP 67 | ||||||||||
| Tests / approvals EMC | EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | |||||||||
| EN 61000-4-3 HF radiated: | 10 V/m | ||||||||||
| EN 61000-4-4 Burst: | 2 kV | ||||||||||
| EN 61000-4-6 HF conducted: | 10 V | ||||||||||
| Shock resistance | 400 g | ||||||||||
| MTTF [Years] | 510 | ||||||||||
| Mechanical data | |||||||||||
| Type of sensor | Microelectromechanical system (MEMS) | ||||||||||
| Number of measurement axes | 1 | ||||||||||
| Housing | materials | PBT (Pocan); PC (Makrolon); FPM (Viton); stainless steel 316L / 1.4404 | |||||||||
| Weight | [kg] | 0.116 | |||||||||
| Displays / operating elements Display | Operation LED green Switching status LED yellow | ||||||||||
| Electrical connection | |||||||||||
| Wiring | |||||||||||
1: L+ | |||||||||||
| 2: 4...20 mA | |||||||||||
| 3: GND | |||||||||||
| 4: digital output (normally | |||||||||||
| closed) | |||||||||||
|