| Sign In | Join Free | My burrillandco.com | 
              
  | 
      
| Ask Lasest Price | |
| Brand Name : | IFM | 
| Model Number : | PN7092 | 
| Price : | $300-$500 | 
| Payment Terms : | T/T, L/C | 
| Supply Ability : | 30pcs/month | 
| Delivery Time : | 3-5days | 

Product characteristics  | |||
| Number of inputs and outputs | Number of digital outputs: 2 | ||
| Measuring range | 0...100 bar | 0...1450 psi | 0...10 MPa | 
| Process connection | threaded connection G 1/4 Internal thread | ||
Application  | |||
| System | gold-plated contacts | ||
| Measuring element | ceramic-capacitive pressure measuring cell | ||
| Application | for industrial applications | ||
| Media | Liquids | ||
| Conditionally suitable for | use in gases at pressures > 25 bar only on request | ||
| Medium temperature [°C] | -25...80 | ||
| Min. bursting pressure | 650 bar | 9400 psi | 65 MPa | 
| Pressure rating | 300 bar | 4350 psi | 30 MPa | 
| Vacuum resistance [mbar] | -1000 | ||
| Type of pressure | relative pressure | ||
Electrical data  | |||
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||
| Current consumption [mA] | < 35 | ||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||
| Protection class | III | ||
| Reverse polarity protection | yes | ||
| Power-on delay time [s] | < 0.3 | ||
| Integrated watchdog | yes | ||
Inputs / outputs  | |||
| Number of inputs and outputs | Number of digital outputs: 2 | ||
Outputs  | |||
| Total number of outputs | 2 | ||
| Output signal | switching signal; IO-Link; (configurable) | ||
| Electrical design | PNP/NPN | ||
| Number of digital outputs | 2 | ||
| Output function | normally open / closed; (configurable) | ||
| Max. voltage drop switching output DC [V] | 2.5 | ||
| Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||
| Switching frequency DC [Hz] | < 170 | ||
| Short-circuit protection | yes | ||
| Type of short-circuit protection | yes (non-latching) | ||
| Overload protection | yes | ||
Measuring/setting range  | |||
| Measuring range | 0...100 bar | 0...1450 psi | 0...10 MPa | 
Factory setting / CMPT = 2  | |||
| Set point SP | 1...100 bar | 10...1450 psi | 0.1...10 MPa | 
| Reset point rP | 0.5...99.5 bar | 5...1445 psi | 0.05...9.95 MPa | 
| Min. difference between SP and rP | 0.5 bar | 10 psi | 0.05 MPa | 
| In steps of | 0.5 bar | 5 psi | 0.05 MPa | 
Status_B High Resolution / CMPT = 3  | |||
| Set point SP | 0.8...100 bar | 12...1450 psi | 0.08...10 MPa | 
| Reset point rP | 0.3...99.5 bar | 5...1443 psi | 0.03...9.95 MPa | 
| Min. difference between SP and rP | 0.5 bar | 8 psi | 0.05 MPa | 
| In steps of | 0.1 bar | 1 psi | 0.01 MPa | 
Accuracy / deviations  | |||
| Switch point accuracy [% of the span] | < ± 0,5 | ||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | ||
| Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | ||
Reaction times  | |||
| Response time [ms] | < 3 | ||
| Delay time programmable dS, dr [s] | 0...50 | ||
Software / programming  | |||
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||
Interfaces  | |||
| Communication interface | IO-Link | ||
| Transmission type | COM2 (38,4 kBaud) | ||
| IO-Link revision | 1.1 | ||
| SDCI standard | IEC 61131-9 | ||
| SIO mode | yes | ||
| Required master port class | A; (when pin 2 not connected: B) | ||
| Process data analog | 1 | ||
| Process data binary | 2 | ||
| Supported DeviceIDs | Type of operation | DeviceID | |
| Factory setting / CMPT = 2 | 401 | ||
| PN7002 | 309 | ||
| Status_B High Resolution / CMPT = 3 | 599 | ||
| Note | For further information please see the IODD PDF file at "Downloads" | ||
                                 
                             |